VitaGuard® VG 2100 - The Heart Rate and Apnea Monitor

Identifying Risks– Reducing Risks

There are many risk groups, ranging from newborns to elderly people, that require constant monitoring of their physiological parameters as part of their medical care. getemed's VitaGuard® monitors provide the possibility of safely and effectively monitoring vital signs in both home and clinical environments.

Easy to Use – Innovative Monitoring

The VitaGuard® monitors are intuitive to operate and, at the same time, provide a wide range of functionality. Also, due to their compact size and light weight, they offer a high degree of flexibility. Features including storage of silent alarms for all monitored parameters as well as additional manual storage of physiological signals extend the application spectrum of the devices. Measurement functions for basal impedance as well as ECG and respiration amplitudes simplify device operation and, coupled with complex signal processing algorithms, increase the reliability.

 
Screenshot VitaWin®

 The high-resolution graphical LCD display enhances intuitive operation and allows simultaneous visual inspection of the measured parameters, alarm settings, waveforms and status messages. Acoustic and visual alarms are generated when the physiological parameters move outside their respective preset alarm limits. When an alarm occurs, the physiological parameters and their associated waveforms are stored in event memory. Parallel to the event driven memory functions, VitaGuard® incorporates a 72-hours trend memory along with an 8-hour full-disclosure memory. getemed's software tool VitaWin® is available to download, visualize and analyze the stored data.

VitaGuard® VG 2100

The monitor displays:
  • Heart rate
  • Respiration rate
  • Type of alarm (e. g. apnea*, bradycardia etc.)
  • Playback function to view stored alarm events (waveforms and trends before, during and after an alarm event)
  • Alarm limits
  • ECG and respiration waveforms

VitaGuard® VG 2100 provides an alarm when no respiration or movement is detected for a preset time i. e. central apnea, or when the patient's heart rate exceeds or falls below preset limits.

*VitaGuard® VG 2100 does not detect obstructive apnea


Medizin- und Informationstechnik AG
Oderstrasse 77
14513 Teltow
Germany

Telephone +49 3328 3942-0
Telefax +49 3328 3942-99
E-Mail info@getemed.de
Internet www.getemed.de